Check the sanity of the synchronized clock by comparing its uncorrected frequency with the system monotonic clock. When the measured frequency offset is larger than the value of the sanity_freq_limit option (20% by default), a warning message will be printed and the servo will be reset. Setting the option to zero disables the check. This is useful to detect when the clock is broken or adjusted by another program. Signed-off-by: Miroslav Lichvar <mlichvar@redhat.com>
447 lines
15 KiB
Groff
447 lines
15 KiB
Groff
.TH PTP4l 8 "October 2013" "linuxptp"
|
|
.SH NAME
|
|
ptp4l \- PTP Boundary/Ordinary Clock
|
|
|
|
.SH SYNOPSIS
|
|
.B ptp4l
|
|
[
|
|
.B \-AEP246HSLmqsv
|
|
] [
|
|
.BI \-f " config"
|
|
] [
|
|
.BI \-p " phc-device"
|
|
] [
|
|
.BI \-l " print-level"
|
|
]
|
|
[
|
|
.BI \-i " interface"
|
|
]
|
|
.I .\|.\|.
|
|
|
|
.SH DESCRIPTION
|
|
.B ptp4l
|
|
is an implementation of the Precision Time Protocol (PTP) according to IEEE
|
|
standard 1588 for Linux. It implements Boundary Clock (BC) and Ordinary Clock
|
|
(OC).
|
|
|
|
.SH OPTIONS
|
|
.TP
|
|
.B \-A
|
|
Select the delay mechanism automatically. Start with E2E and switch to P2P when
|
|
a peer delay request is received.
|
|
.TP
|
|
.B \-E
|
|
Select the delay request-response (E2E) mechanism. This is the default
|
|
mechanism. All clocks on single PTP communication path must use the same
|
|
mechanism. A warning will be printed when a peer delay request is received on
|
|
port using the E2E mechanism.
|
|
.TP
|
|
.B \-P
|
|
Select the peer delay (P2P) mechanism. A warning will be printed when a delay
|
|
request is received on port using the P2P mechanism.
|
|
.TP
|
|
.B \-2
|
|
Select the IEEE 802.3 network transport.
|
|
.TP
|
|
.B \-4
|
|
Select the UDP IPv4 network transport. This is the default transport.
|
|
.TP
|
|
.B \-6
|
|
Select the UDP IPv6 network transport.
|
|
.TP
|
|
.B \-H
|
|
Select the hardware time stamping. All ports specified by the
|
|
.B \-i
|
|
option and in the configuration file must be attached to the same PTP hardware
|
|
clock (PHC). This is the default time stamping.
|
|
.TP
|
|
.B \-S
|
|
Select the software time stamping.
|
|
.TP
|
|
.B \-L
|
|
Select the legacy hardware time stamping.
|
|
.TP
|
|
.BI \-f " config"
|
|
Read configuration from the specified file. No configuration file is read by
|
|
default.
|
|
.TP
|
|
.BI \-i " interface"
|
|
Specify a PTP port, it may be used multiple times. At least one port must be
|
|
specified by this option or in the configuration file.
|
|
.TP
|
|
.BI \-p " phc-device"
|
|
With hardware time stamping, force which PHC device (e.g. /dev/ptp0) should be
|
|
used.
|
|
.TP
|
|
.B \-s
|
|
Enable the slaveOnly mode.
|
|
.TP
|
|
.BI \-l " print-level"
|
|
Set the maximum syslog level of messages which should be printed or sent to
|
|
the system logger. The default is 6 (LOG_INFO).
|
|
.TP
|
|
.B \-m
|
|
Print messages to the standard output.
|
|
.TP
|
|
.B \-q
|
|
Don't send messages to the system logger.
|
|
.TP
|
|
.B \-v
|
|
Prints the software version and exits.
|
|
.TP
|
|
.BI \-h
|
|
Display a help message.
|
|
|
|
.SH CONFIGURATION FILE
|
|
|
|
The configuration file is divided into sections. Each section starts with a
|
|
line containing its name enclosed in brackets and it follows with settings.
|
|
Each setting is placed on a separate line, it contains the name of the
|
|
option and the value separated by whitespace characters. Empty lines and lines
|
|
starting with # are ignored.
|
|
|
|
The global section (indicated as
|
|
.BR [global] )
|
|
sets the program options, clock options and default port options. Other
|
|
sections are port specific sections and they override the default port options.
|
|
The name of the section is the name of the configured port (e.g.
|
|
.BR [eth0] ).
|
|
Ports specified in the configuration file don't need to be
|
|
specified by the
|
|
.B \-i
|
|
option. An empty port section can be used to replace the command line option.
|
|
|
|
.SH PORT OPTIONS
|
|
|
|
.TP
|
|
.B delayAsymmetry
|
|
The time difference in nanoseconds of the transmit and receive
|
|
paths. This value should be positive when the master-to-slave
|
|
propagation time is longer and negative when the slave-to-master time
|
|
is longer. The default is 0 nanoseconds.
|
|
.TP
|
|
.B logAnnounceInterval
|
|
The mean time interval between Announce messages. A shorter interval makes
|
|
ptp4l react faster to the changes in the master-slave hierarchy. The interval
|
|
should be the same in the whole domain. It's specified as a power of two in
|
|
seconds.
|
|
The default is 1 (2 seconds).
|
|
.TP
|
|
.B logSyncInterval
|
|
The mean time interval between Sync messages. A shorter interval may improve
|
|
accuracy of the local clock. It's specified as a power of two in seconds.
|
|
The default is 0 (1 second).
|
|
.TP
|
|
.B logMinDelayReqInterval
|
|
The minimum permitted mean time interval between Delay_Req messages. A shorter
|
|
interval makes ptp4l react faster to the changes in the path delay. It's
|
|
specified as a power of two in seconds.
|
|
The default is 0 (1 second).
|
|
.TP
|
|
.B logMinPdelayReqInterval
|
|
The minimum permitted mean time interval between Pdelay_Req messages. It's
|
|
specified as a power of two in seconds.
|
|
The default is 0 (1 second).
|
|
.TP
|
|
.B announceReceiptTimeout
|
|
The number of missed Announce messages before the last Announce messages
|
|
expires.
|
|
The default is 3.
|
|
.TP
|
|
.B syncReceiptTimeout
|
|
The number of sync/follow up messages that may go missing before
|
|
triggering a Best Master Clock election. This option is used for
|
|
running in gPTP mode according to the 802.1AS-2011 standard. Setting
|
|
this option to zero will disable the sync message timeout.
|
|
The default is 0 or disabled.
|
|
.TP
|
|
.B transportSpecific
|
|
The transport specific field. Must be in the range 0 to 255.
|
|
The default is 0.
|
|
.TP
|
|
.B path_trace_enabled
|
|
Enable the mechanism used to trace the route of the Announce messages.
|
|
The default is 0 (disabled).
|
|
.TP
|
|
.B follow_up_info
|
|
Include the 802.1AS data in the Follow_Up messages if enabled.
|
|
The default is 0 (disabled).
|
|
.TP
|
|
.B fault_reset_interval
|
|
The time in seconds between the detection of a port's fault and the fault
|
|
being reset. This value is expressed as a power of two. Setting this
|
|
value to -128 or to the special key word "ASAP" will let the fault be
|
|
reset immediately.
|
|
The default is 4 (16 seconds).
|
|
.TP
|
|
.B fault_badpeernet_interval
|
|
The time in seconds between the detection of a peer network misconfiguration
|
|
and the fault being reset. The port is disabled for the duration of the
|
|
interval. The value is in seconds and the special key word ASAP will let
|
|
the fault be reset immediately.
|
|
The default is 16 seconds.
|
|
.TP
|
|
.B delay_mechanism
|
|
Select the delay mechanism. Possible values are E2E, P2P and Auto.
|
|
The default is E2E.
|
|
.TP
|
|
.B network_transport
|
|
Select the network transport. Possible values are UDPv4, UDPv6 and L2.
|
|
The default is UDPv4.
|
|
.TP
|
|
.B neighborPropDelayThresh
|
|
Upper limit for peer delay in nanoseconds. If the estimated peer delay is
|
|
greater than this value the port is marked as not 802.1AS capable.
|
|
|
|
.SH PROGRAM AND CLOCK OPTIONS
|
|
|
|
.TP
|
|
.B twoStepFlag
|
|
Enable two-step mode for sync messages. One-step mode can be used only with
|
|
hardware time stamping.
|
|
The default is 1 (enabled).
|
|
.TP
|
|
.B slaveOnly
|
|
The local clock is a slave-only clock if enabled.
|
|
The default is 0 (disabled).
|
|
.TP
|
|
.B priority1
|
|
The priority1 attribute of the local clock. It is used in the best master
|
|
selection algorithm, lower values take precedence. Must be in the range 0 to
|
|
255.
|
|
The default is 128.
|
|
.TP
|
|
.B priority2
|
|
The priority2 attribute of the local clock. It is used in the best master
|
|
selection algorithm, lower values take precedence. Must be in the range 0 to
|
|
255.
|
|
The default is 128.
|
|
.TP
|
|
.B clockClass
|
|
The clockClass attribute of the local clock. It denotes the traceability of the
|
|
time distributed by the grandmaster clock.
|
|
The default is 248.
|
|
.TP
|
|
.B clockAccuracy
|
|
The clockAccuracy attribute of the local clock. It is used in the best master
|
|
selection algorithm.
|
|
The default is 0xFE.
|
|
.TP
|
|
.B offsetScaledLogVariance
|
|
The offsetScaledLogVariance attribute of the local clock. It characterizes the
|
|
stability of the clock.
|
|
The default is 0xFFFF.
|
|
.TP
|
|
.B domainNumber
|
|
The domain attribute of the local clock.
|
|
The default is 0.
|
|
.TP
|
|
.B free_running
|
|
Don't adjust the local clock if enabled.
|
|
The default is 0 (disabled).
|
|
.TP
|
|
.B freq_est_interval
|
|
The time interval over which is estimated the ratio of the local and
|
|
peer clock frequencies. It is specified as a power of two in seconds.
|
|
The default is 1 (2 seconds).
|
|
.TP
|
|
.B assume_two_step
|
|
Treat one-step responses as two-step if enabled. It is used to work around
|
|
buggy 802.1AS switches.
|
|
The default is 0 (disabled).
|
|
.TP
|
|
.B tx_timestamp_timeout
|
|
The number of milliseconds to poll waiting for the tx time stamp from the kernel
|
|
when a message has recently been sent.
|
|
The default is 1.
|
|
.TP
|
|
.B check_fup_sync
|
|
Because of packet reordering that can occur in the network, in the
|
|
hardware, or in the networking stack, a follow up message can appear
|
|
to arrive in the application before the matching sync message. As this
|
|
is a normal occurrence, and the sequenceID message field ensures
|
|
proper matching, the ptp4l program accepts out of order packets. This
|
|
option adds an additional check using the software time stamps from
|
|
the networking stack to verify that the sync message did arrive
|
|
first. This option is only useful if you do not trust the sequence IDs
|
|
generated by the master.
|
|
The default is 0 (disabled).
|
|
.TP
|
|
.B clock_servo
|
|
The servo which is used to synchronize the local clock. Currently only one
|
|
servo is implemented, a PI controller.
|
|
The default is pi.
|
|
.TP
|
|
.B pi_proportional_const
|
|
The proportional constant of the PI controller. When set to 0.0, the
|
|
proportional constant will be set by the following formula from the current
|
|
sync interval.
|
|
The default is 0.0.
|
|
|
|
kp = min(kp_scale * sync^kp_exponent, kp_norm_max / sync))
|
|
.TP
|
|
.B pi_integral_const
|
|
The integral constant of the PI controller. When set to 0.0, the
|
|
integral constant will be set by the following formula from the current
|
|
sync interval.
|
|
The default is 0.0.
|
|
|
|
ki = min(ki_scale * sync^ki_exponent, ki_norm_max / sync)
|
|
.TP
|
|
.B pi_proportional_scale
|
|
The kp_scale constant in the formula used to set the proportional constant of
|
|
the PI controller from the sync interval. When set to 0.0, the value will be
|
|
selected from 0.7 and 0.1 for the hardware and software time stamping
|
|
respectively.
|
|
The default is 0.0.
|
|
.TP
|
|
.B pi_proportional_exponent
|
|
The kp_exponent constant in the formula used to set the proportional constant of
|
|
the PI controller from the sync interval.
|
|
The default is -0.3.
|
|
.TP
|
|
.B pi_proportional_norm_max
|
|
The kp_norm_max constant in the formula used to set the proportional constant of
|
|
the PI controller from the sync interval.
|
|
The default is 0.7
|
|
.TP
|
|
.B pi_integral_scale
|
|
The ki_scale constant in the formula used to set the integral constant of
|
|
the PI controller from the sync interval. When set to 0.0, the value will be
|
|
selected from 0.3 and 0.001 for the hardware and software time stamping
|
|
respectively.
|
|
The default is 0.0.
|
|
.TP
|
|
.B pi_integral_exponent
|
|
The ki_exponent constant in the formula used to set the integral constant of
|
|
the PI controller from the sync interval.
|
|
The default is 0.4.
|
|
.TP
|
|
.B pi_integral_norm_max
|
|
The ki_norm_max constant in the formula used to set the integral constant of
|
|
the PI controller from the sync interval.
|
|
The default is 0.3.
|
|
.TP
|
|
.B pi_offset_const
|
|
The maximum offset the PI controller will correct by changing the clock
|
|
frequency instead of stepping the clock. When set to 0.0, the controller will
|
|
never step the clock except on start.
|
|
The default is 0.0.
|
|
.TP
|
|
.B pi_f_offset_const
|
|
The maximum offset the PI controller will correct by changing the clock
|
|
frequency instead of stepping the clock. This is only applied on the first
|
|
update. When set to 0.0, the controller won't step the clock on start.
|
|
The default is 0.0000001 (100 nanoseconds).
|
|
.TP
|
|
.B pi_max_frequency
|
|
The maximum allowed frequency adjustment of the clock in parts per billion
|
|
(ppb). This is an additional limit to the maximum allowed by the hardware. When
|
|
set to 0, the hardware limit will be used.
|
|
The default is 900000000 (90%).
|
|
.TP
|
|
.B sanity_freq_limit
|
|
The maximum allowed frequency offset between uncorrected clock and the system
|
|
monotonic clock in parts per billion (ppb). This is used as a sanity check of
|
|
the synchronized clock. When a larger offset is measured, a warning message
|
|
will be printed and the servo will be reset. When set to 0, the sanity check is
|
|
disabled. The default is 200000000 (20%).
|
|
.TP
|
|
.B ptp_dst_mac
|
|
The MAC address where should be PTP messages sent.
|
|
Relevant only with L2 transport. The default is 01:1B:19:00:00:00.
|
|
.TP
|
|
.B p2p_dst_mac
|
|
The MAC address where should be peer delay messages the PTP peer.
|
|
Relevant only with L2 transport. The default is 01:80:C2:00:00:0E.
|
|
.TP
|
|
.B udp6_scope
|
|
Specifies the desired scope for the IPv6 multicast messages. This
|
|
will be used as the second byte of the primary address. This option
|
|
is only relevant with IPv6 transport. See RFC 4291. The default is
|
|
0x0E for the global scope.
|
|
.TP
|
|
.B uds_address
|
|
Specifies the address of the UNIX domain socket for receiving local
|
|
management messages. The default is /var/run/ptp4l.
|
|
.TP
|
|
.B logging_level
|
|
The maximum logging level of messages which should be printed.
|
|
The default is 6 (LOG_INFO).
|
|
.TP
|
|
.B verbose
|
|
Print messages to the standard output if enabled.
|
|
The default is 0 (disabled).
|
|
.TP
|
|
.B use_syslog
|
|
Print messages to the system log if enabled.
|
|
The default is 1 (enabled).
|
|
.TP
|
|
.B summary_interval
|
|
The time interval in which are printed summary statistics of the clock. It is
|
|
specified as a power of two in seconds. The statistics include offset root mean
|
|
square (RMS), maximum absolute offset, frequency offset mean and standard
|
|
deviation, and path delay mean and standard deviation. The units are
|
|
nanoseconds and parts per billion (ppb). If there is only one clock update in
|
|
the interval, the sample will be printed instead of the statistics. The
|
|
messages are printed at the LOG_INFO level.
|
|
The default is 0 (1 second).
|
|
.TP
|
|
.B time_stamping
|
|
The time stamping method. The allowed values are hardware, software and legacy.
|
|
The default is hardware.
|
|
.TP
|
|
.B productDescription
|
|
The product description string. Allowed values must be of the form
|
|
manufacturerName;modelNumber;instanceIdentifier and contain at most 64
|
|
utf8 symbols. The default is ";;".
|
|
.TP
|
|
.B revisionData
|
|
The revision description string which contains the revisions for node
|
|
hardware (HW), firmware (FW), and software (SW). Allowed values are of
|
|
the form HW;FW;SW and contain at most 32 utf8 symbols. The default is
|
|
an ";;".
|
|
.TP
|
|
.B userDescription
|
|
The user description string. Allowed values are of the form
|
|
name;location and contain at most 128 utf8 symbols. The default is an
|
|
empty string.
|
|
.TP
|
|
.B manufacturerIdentity
|
|
The manufacturer id which should be an OUI owned by the manufacturer.
|
|
The default is 00:00:00.
|
|
.TP
|
|
.B kernel_leap
|
|
When a leap second is announced, let the kernel apply it by stepping the clock
|
|
instead of correcting the one-second offset with servo, which would correct the
|
|
one-second offset slowly by changing the clock frequency (unless the
|
|
.B pi_offset_const
|
|
option is set to correct such offset by stepping).
|
|
Relevant only with software time stamping. The default is 1 (enabled).
|
|
.TP
|
|
.B timeSource
|
|
The time source is a single byte code that gives an idea of the kind
|
|
of local clock in use. The value is purely informational, having no
|
|
effect on the outcome of the Best Master Clock algorithm, and is
|
|
advertised when the clock becomes grand master.
|
|
|
|
.SH TIME SCALE USAGE
|
|
|
|
.B ptp4l
|
|
as domain master either uses PTP or UTC time scale depending on time stamping
|
|
mode. In software and legacy time stamping modes it announces Arbitrary time
|
|
scale mode, which is effectively UTC here, in hardware time stamping mode it
|
|
announces use of PTP time scale.
|
|
|
|
When
|
|
.B ptp4l
|
|
is the domain master using hardware time stamping, it is up to
|
|
.B phc2sys
|
|
to maintain the correct offset between UTC and PTP times. See
|
|
.BR phc2sys (8)
|
|
manual page for more details.
|
|
|
|
.SH SEE ALSO
|
|
.BR pmc (8),
|
|
.BR phc2sys (8)
|