.TH NSM 8 "June 2019" "linuxptp"
.SH NAME
nsm \- NetSync Monitor client
.SH SYNOPSIS
.B nsm
[
.BI \-f " config"
] [
.BI \-i " interface"
] [
.I long-options
] [ command ] ...
.SH DESCRIPTION
.B nsm
is a program which implements a NetSync Monitor (NSM) client. NSM is an
extension to the Precision Time Protocol (PTP), which enables a client to
measure the offset of its clock against any PTP clock in the network which
supports NSM. It uses unicast messages, but unlike PTP in the unicast mode it
does not require the server to keep any state specific to the client. It is
particularly useful for monitoring.
The program reads commands from the standard input or from the command line.
.SH COMMANDS
.TP
.BI NSM " address"
Send a NetSync Monitor request to the specified network address (IPv4 or MAC)
and print the measured offset with the response.
.TP
.B help
Display a help message.
.SH OPTIONS
.TP
.BI \-f " config"
Read configuration from the specified file. No configuration file is read by
default.
.TP
.BI \-i " interface"
Specify the network interface.
.TP
.B \-h
Display a help message.
.TP
.B \-v
Print the software version and exit.
.SH LONG OPTIONS
Each and every configuration file option (see below in sections
.BR PROGRAM\ OPTIONS
and
.BR PORT\ OPTIONS )
may also appear
as a "long" style command line argument. For example, the transportSpecific
option may be set using either of these two forms:
.RS
\f(CW\-\-transportSpecific 1 \-\-transportSpecific=1\fP
.RE
Option values given on the command line override values in the global
section of the configuration file (which, in turn, overrides default
values).
.SH CONFIGURATION FILE
The configuration file is divided into sections. Each section starts with a
line containing its name enclosed in brackets and it follows with settings.
Each setting is placed on a separate line, it contains the name of the
option and the value separated by whitespace characters. Empty lines and lines
starting with # are ignored.
The global section (indicated as
.BR [global] )
sets the global program options as well as the default port specific options.
Other sections are port specific sections and they override the default port
options. The name of the section is the name of the configured port (e.g.
.BR [eth0]
).
.SH PORT OPTIONS
.TP
.B delayAsymmetry
The time difference in nanoseconds of the transmit and receive
paths. This value should be positive when the master-to-slave
propagation time is longer and negative when the slave-to-master time
is longer. The default is 0 nanoseconds.
.TP
.B network_transport
Select the network transport. Possible values are UDPv4 and L2. The default
is UDPv4.
.TP
.B transportSpecific
The transport specific field. Must be in the range 0 to 255.
The default is 0.
.SH PROGRAM OPTIONS
.TP
.B domainNumber
The domain attribute of the local clock. The default is 0.
.B time_stamping
The time stamping method. The allowed values are hardware, software and legacy.
The default is hardware.
.SH WARNING
Be cautious when the same configuration file is used for both ptp4l
and nsm. Keep in mind that values specified in the configuration file
take precedence over their default values. If a certain option which
is common to ptp4l and nsm is specified to a non-default value in the
configuration file (e.g. for ptp4l), then this non-default value
applies also for nsm. This might be not what is expected.
To avoid securely these unexpected behaviour, different configuration files
for ptp4l and nsm are recommended.
.SH SEE ALSO
.BR ptp4l (8)