phc2sys.c: Sync variable 'node.sanity_freq_limit with cfg item
Copy 'node.sanity_freq_limit' to struct config item 'sanity_freq_limit'. Check for 'servo_type' == CLOCK_SERVO_NTPSHM. Signed-off-by: Peter Schneider <peter@psch.de>master
parent
c22864a807
commit
26308c219a
|
@ -1349,7 +1349,6 @@ int main(int argc, char *argv[])
|
||||||
int ntpshm_segment;
|
int ntpshm_segment;
|
||||||
double phc_rate, tmp;
|
double phc_rate, tmp;
|
||||||
struct node node = {
|
struct node node = {
|
||||||
.sanity_freq_limit = 200000000,
|
|
||||||
.phc_readings = 5,
|
.phc_readings = 5,
|
||||||
.phc_interval = 1.0,
|
.phc_interval = 1.0,
|
||||||
};
|
};
|
||||||
|
@ -1445,8 +1444,10 @@ int main(int argc, char *argv[])
|
||||||
node.forced_sync_offset = -1;
|
node.forced_sync_offset = -1;
|
||||||
break;
|
break;
|
||||||
case 'L':
|
case 'L':
|
||||||
if (get_arg_val_i(c, optarg, &node.sanity_freq_limit, 0, INT_MAX))
|
if (get_arg_val_i(c, optarg, &node.sanity_freq_limit, 0, INT_MAX) ||
|
||||||
|
config_set_int(cfg, "sanity_freq_limit", node.sanity_freq_limit)) {
|
||||||
goto end;
|
goto end;
|
||||||
|
}
|
||||||
break;
|
break;
|
||||||
case 'M':
|
case 'M':
|
||||||
if (get_arg_val_i(c, optarg, &ntpshm_segment, INT_MIN, INT_MAX) ||
|
if (get_arg_val_i(c, optarg, &ntpshm_segment, INT_MIN, INT_MAX) ||
|
||||||
|
@ -1548,8 +1549,10 @@ int main(int argc, char *argv[])
|
||||||
node.servo_type = config_get_int(cfg, NULL, "clock_servo");
|
node.servo_type = config_get_int(cfg, NULL, "clock_servo");
|
||||||
if (node.servo_type == CLOCK_SERVO_NTPSHM) {
|
if (node.servo_type == CLOCK_SERVO_NTPSHM) {
|
||||||
config_set_int(cfg, "kernel_leap", 0);
|
config_set_int(cfg, "kernel_leap", 0);
|
||||||
|
config_set_int(cfg, "sanity_freq_limit", 0);
|
||||||
}
|
}
|
||||||
node.kernel_leap = config_get_int(cfg, NULL, "kernel_leap");
|
node.kernel_leap = config_get_int(cfg, NULL, "kernel_leap");
|
||||||
|
node.sanity_freq_limit = config_get_int(cfg, NULL, "sanity_freq_limit");
|
||||||
|
|
||||||
if (autocfg) {
|
if (autocfg) {
|
||||||
if (init_pmc(cfg, &node))
|
if (init_pmc(cfg, &node))
|
||||||
|
|
Loading…
Reference in New Issue