diff --git a/phc2sys.8 b/phc2sys.8 index 4fc4fa3..3a8683e 100644 --- a/phc2sys.8 +++ b/phc2sys.8 @@ -1,4 +1,4 @@ -.TH PHC2SYS 8 "November 2012" "linuxptp" +.TH PHC2SYS 8 "April 2018" "linuxptp" .SH NAME phc2sys \- synchronize two or more clocks @@ -8,10 +8,16 @@ phc2sys \- synchronize two or more clocks .B \-r ] [ .B \-r -] [ options ] +] [ +.BI \-f " config-file" +] [ options ] [ +.I long-options +] .br .B phc2sys [ +.BI \-f " config-file" +] [ .BI \-d " pps-device" ] [ .BI \-s " device" @@ -21,7 +27,11 @@ phc2sys \- synchronize two or more clocks .BI \-O " offset" ] [ .BI \-w -] [ options ] +] [ options ] [ +.I long-options +] +.I .\|.\|. + .SH DESCRIPTION .B phc2sys @@ -67,6 +77,10 @@ system clock to be eligible to become a time source, specify the .B \-r option twice. .TP +.BI \-f " config" +Read configuration from the specified file. No configuration file is read by +default. +.TP .BI \-d " pps-device" Specify the PPS device of the master clock (e.g. /dev/pps0). With this option the PPS synchronization mode is used instead of the direct mode. As the PPS @@ -226,6 +240,167 @@ Display a help message. .B \-v Prints the software version and exits. +.SH LONG OPTIONS + +Each and every configuration file option (see below in section +.BR FILE\ OPTIONS) +may also appear +as a "long" style command line argument. For example, the transportSpecific +option may be set using either of these two forms: + +.RS +\f(CW\-\-transportSpecific 1 \-\-transportSpecific=1\fP +.RE + +Option values given on the command line override values in the global +section of the configuration file (which, in turn overrides default +values). + +.SH CONFIGURATION FILE + +The configuration file is divided into sections. Each section starts with a +line containing its name enclosed in brackets and it follows with settings. +Each setting is placed on a separate line, it contains the name of the +option and the value separated by whitespace characters. Empty lines and lines +starting with # are ignored. + +The global section (indicated as +.BR [global] ) +sets the program options. This is the only used option. + +.SH FILE OPTIONS + +.TP +.B domainNumber +Specify the domain number used by phc2sys. The default is 0. Same as option +.B \-n +(see above). + +.TP +.B kernel_leap +When a leap second is announced, let the kernel apply it by stepping the +clock instead of correcting the one-second offset with servo, which would +correct the one-second offset slowly by changing the clock frequency +(unless the step_threshold option is set to correct such offset by +stepping). Relevant only with software time stamping. The default is 1 +(enabled). Same as option +.B \-x +(see above). + +The maximum logging level of messages which should be printed. +The default is 6 (LOG_INFO). Same as option +.B \-l +(see above). + +.TP +.B logging_level +The maximum logging level of messages which should be printed. +The default is 6 (LOG_INFO). Same as option +.B \-l +(see above). + +.TP +.B message_tag +The tag which is added to all messages printed to the standard output +or system log. The default is an empty string (which cannot be set in +the configuration file as the option requires an argument). +Same as option +.B \-t +(see above). + +.TP +.B sanity_freq_limit +The maximum allowed frequency offset between uncorrected clock and the +system monotonic clock in parts per billion (ppb). This is used as a +sanity check of the synchronized clock. When a larger offset is measured, +a warning message will be printed and the servo will be reset. When set +to 0, the sanity check is disabled. The default is 200000000 (20%). +Same as option +.B \-L +(see above). + +.TP +.B clock_servo +The servo which is used to synchronize the local clock. Valid values +are "pi" for a PI controller, "linreg" for an adaptive controller using +linear regression, "ntpshm" for the NTP SHM reference clock to allow +another process to synchronize the local clock (the SHM segment number +is set to the domain number), and "nullf" for a servo that always dials +frequency offset zero (for use in SyncE nodes). The default is "pi." +Same as option +.B \-E +(see above). + +.TP +.B transportSpecific +The transport specific field. Must be in the range 0 to 255. +The default is 0. + +.TP +.B use_syslog +Print messages to the system log if enabled. The default is 1 (enabled). +Related to option +.B \-q +(see above). + +.TP +.B verbose +Print messages to the standard output if enabled. The default is 0 (disabled). +Related to option +.B \-m +(see above). + +.TP +.B pi_proportional_const +Specifies the proportional constant of the PI controller. +Same as option +.B \-P +(see above). + +.TP +.B pi_integral_const +Specifies the integral constant of the PI controller. +Same as option +.B \-I +(see above). + +.TP +.B step_threshold +Specifies the step threshold of the servo. It is the maximum offset that +the servo corrects by changing the clock frequency instead of stepping +the clock. The clock is stepped on start regardless of the option if the +offset is larger than 20 microseconds (unless the -F option is used). +It's specified in seconds. The value of 0.0 disables stepping after +the start. The default is 0.0. +Same as option +.B \-S +(see above). + +.TP +.B first_step_threshold +Specify the step threshold applied only on the first update. It is the +maximum offset that is corrected by adjusting clock. It's specified in +seconds. The value of 0.0 disables stepping on start. The default is +0.00002 (20 microseconds). +Same as option +.B \-F +(see above). + +.TP +.B ntpshm_segment +The number of the SHM segment used by ntpshm servo. The default is 0. +Same as option +.B \-M +(see above). + +.TP +.B uds_address +Specifies the address of the server's UNIX domain socket. The default +is /var/run/ptp4 +Same as option +.B \-z +(see above). + .SH TIME SCALE USAGE .B Ptp4l @@ -269,6 +444,12 @@ in the domain to its system clock. \f(CWphc2sys \-a \-rr\fP .RE +Same as above, in an IEEE 802.1AS domain. + +.RS +\f(CWphc2sys \-a \-rr --transportSpecific=1\fP +.RE + The host is a domain master, PTP clock is synchronized to system clock and the time offset is obtained from .BR ptp4l . @@ -310,5 +491,17 @@ does not wait. \f(CWphc2sys \-s eth0 \-O \-35\fP .RE +.SH WARNING + +Be cautious when the same configuration file is used for both ptp4l and phc2sys. +Keep in mind, that values specified in the configuration file take precedence +over their default values. If a certain option, which is common to ptp4l and +phc2sys, is specified to a non-default value in the configuration file +(p.e., for ptp4l), then this non-default value applies also for phc2sys. This +might be not what is expected. + +It is recommended to use seperate configuration files for ptp4l and +phc2sys in order to avoid any unexpected behavior. + .SH SEE ALSO .BR ptp4l (8)